Weak airflow at the vents.

If the air at the vents feels weak, the system is usually fighting to breathe. Static pressure is how hard the blower is pushing against the filter, the coil & the ducts. Too high, & it moves less air: the coil freezes, the far bedrooms stay warm & the blower motor wears out early.

How hard the blower is fighting is a number we can read: static pressure, explained.

Signs your system can't breathe

  • Weak air at the vents, even with the system running all day.
  • A return grille that whistles, or a filter sucked in & bent.
  • One room that never cools.
  • Ice on the lines or on the coil.
  • Running but not cooling.
  • Dust that comes back a day after you clean.

What causes it

  • Not enough return air. Most SWFL houses are short on it. A three ton system pulling through one small return is common.
  • The filter. Dirty, or too thick for the slot.
  • A dirty coil. The gallery of gross is full of them.
  • Ducts. Crushed flex, a run blown off the plenum, or a duct system that was never sized for the unit.
  • Closed vents. Closing rooms off doesn't save money. It raises the pressure on everything else.

How we find it

We put a gauge on the system & read the pressure, then look for where it's coming from: the filter, the coil, the return or the ducts. Then you get a written price for the fix before anything gets done.

How it gets fixed

  • The right filter, or a filter cabinet that gives it more area.
  • A coil cleaning. AirCare keeps it from coming back.
  • A new return, or a bigger one. Often the single best dollar you spend.
  • Ducts repaired, sealed or replaced. Ductwork & what it costs.

More on air moving

Residential$95$130 after hours
Commercial$125$160 after hours
  • Some of it

    ReturnsA return we added. The system was starving for air & the static pressure said so. The whistling stopped & the coil stopped freezing.
  • ReturnsMaterial for new bedroom returns. A three ton unit breathing through one 14 inch return. Returns in each room fix the warm bedrooms.
  • DuctworkFifteen year old flex, blown clean off the plenum. The homeowner called about low airflow. The attic had been getting most of the house for a while.

Questions people ask

Yes. A clogged filter, or a thick high MERV filter jammed into a slot made for a 1 inch one, can choke the system on its own. We check what the system can take before we recommend one.
No. If the ducts and returns can't move the air, a bigger blower pushes against the same wall. Bigger isn't better. It short cycles & leaves the humidity in.
Usually it means the return is too small for the system & the blower is pulling hard through it. It's one of the most common causes of a coil that freezes.
It starts with the $95 diagnostic ($130 after hours). The fix can be a filter, a coil cleaning, a reconnected duct, or a new return. You get the written price before anything gets fixed.